Large Power Service (LP)

Availability of Service
Available to any customer where three phase service is required. Applicant must be located adjacent to a transmission or distribution line having adequate capacity for the customer's requirements.

Base Rate*

 Customer Charge $98.60 per meter per month
 Maximum Load Charge $17.038 per kW for all kW
 Energy Charge $0.034510 per kWh for all kWh
Base rates are subject to quarterly adjustments to reflect changes in the cost of wholesale power. Please refer to the Tracking Factor for quarterly adjustments.

* Subject to the provisions of the disclaimer and Non-Recurring Charges.


Minimum Charge
The minimum monthly charge shall be the Maximum Load charge.

Determination of Maximum Load and Measurement of Energy
Billing maximum load in kVA shall be taken each month as the highest registration in kilowatts during the month by a 15-minute integrating or thermal type demand meter or indicator divided by the average lagging power factor established during the month corrected to the nearest kVA. Energy will be measured by suitable integrating instruments. For billing purposes the billing maximum load shall be the greater of the maximum load occurring during the month or one hunderd (100) kVA.

Bills computed under this rate schedule will be modified by credits as follows:

  1. Delivery Voltage - When the measurement of energy is made at the primary voltage of the transmission or distribution line used to supply the customer, the maximum load and energy charges will be multiplied by 0.98.
  2. Equipment Supplied by Customer - When customer furnishes and maintains the complete substation equipment including any and all transformers, switches and/or other apparatus necessary to take his entire service at the primary voltage of the transmission or distribution line from which service is received, a credit of $0.30 per kVA of billing maximum load will be applied to each billing.

Off-Peak Service
Those customers with a maximum load of not less than 500 kVA may be served on the basis that their main use of their service will be during the following off-peak periods:

  1. Off-Peak periods shall be all hours between 9:00 p.m. and 9:00 a.m., local time, Monday through Friday, and all hours of the day on Saturdays, Sundays, and legal holidays. Legal holidays shall include New Year's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day.

For billing purposes, the billing maximum load shall be the greater of:

  1. The maximum load occurring during the On-Peak periods of the month
  2. Forty-nine and ninety five hundreds percent (49.95%) of the maximum load occurring during the off-peak periods of the month
  3. Five Hundred(500) kVA.

Term of Service
Service arrangements under this rate schedule will be made for an initial term of not less than one (1) year with a longer term if specified in a contract between the customer and the utility.

Special Terms and Conditions
Service under this rate schedule normally will be supplied through one metering installation. Where customer is served through 2 metering points to the same plant or location primary or transmission voltage, the meter readings may be totaled for billing.However, the Monthly Service Charge will apply for each metering point.